How to find a cable's actual nvp – Fluke Networks CertiFiber Pro Users Manual User Manual
Page 369

Chapter 15: Custom Media and Test Limits
How to Change the NVP
347
Note
If you are on the NEW CUSTOM CABLE screen, tap
the NVP panel, then go to step 4 below.
To enter a specified NVP value
1
On the home screen, tap the test setup panel, tap a copper
test, then tap EDIT.
2
On the TEST SETUP screen, make sure that the Cable Type is
correct.
3
Under the Cable Type, tap NVP.
4
On the NVP screen, use
or
to change the NVP value.
5
Tap DONE, then tap SAVE.
How to Find a Cable's Actual NVP
To find a cable's actual NVP, you can use the NVP screen to adjust
the measured length to match a known length of cable. The NVP
value applies to the selected cable type.
To find a cable's NVP
Note
If you are on the NEW CUSTOM CABLE screen, tap
the NVP panel, then go to step 4 below.
1
On the home screen, tap the test setup panel, tap a copper
test, then tap EDIT.
2
On the TEST SETUP screen, make sure that the Cable Type is
correct.
3
Under the Cable Type, tap NVP.
4
Attach a channel adapter to the tester.
5
Connect a known length of twisted pair cable to the tester.
The cable must be a minimum of 30 m (100 ft) long.
-continued-