Chapter 15: Custom Media and Test Limits

How to Change the NVP

347

Note

If you are on the NEW CUSTOM CABLE screen, tap
the NVP panel, then go to step 4 below.

To enter a specified NVP value

1

On the home screen, tap the test setup panel, tap a copper
test, then tap EDIT.

2

On the TEST SETUP screen, make sure that the Cable Type is
correct.

3

Under the Cable Type, tap NVP.

4

On the NVP screen, use

or

to change the NVP value.

5

Tap DONE, then tap SAVE.

How to Find a Cable's Actual NVP

To find a cable's actual NVP, you can use the NVP screen to adjust
the measured length to match a known length of cable. The NVP
value applies to the selected cable type.

To find a cable's NVP

Note

If you are on the NEW CUSTOM CABLE screen, tap
the NVP panel, then go to step 4 below.

1

On the home screen, tap the test setup panel, tap a copper
test, then tap EDIT.

2

On the TEST SETUP screen, make sure that the Cable Type is
correct.

3

Under the Cable Type, tap NVP.

4

Attach a channel adapter to the tester.

5

Connect a known length of twisted pair cable to the tester.
The cable must be a minimum of 30 m (100 ft) long.

-continued-