CertiFiber Pro OLTS Loss/Length Specifications
Specification
CertiFiber Pro
Multimode Modules
CertiFiber Pro
Singlemode Modules
Testing speeds
(excluding
referencing
times)
Smart Remote mode (2 wavelengths, one direction): 3 s
Far End Source mode
1
(2 wavelengths, one direction): 2 s
Loopback mode (2 wavelengths, one direction): 2 s
Input/output
connectors
Interchangeable connector adapter (LC standard on input,
SC standard on output)
Launch
Condition
Encircled flux compliant to TIA 455-526-14-B,
ISO/IEC 14763-3, and IEC 61280-4-1
2,3
Fiber types
tested
50/125 µm, 62.5/125 µm
multimode fiber
Singlemode fiber
Source type and
wavelengths
Multimode LED source
850 nm 30 nm
1300 nm 20 nm
Fabry-Perot laser diode
1310 nm 20 nm
1550 nm 30 nm
Maximum
length
measurement
12 km
130 km
Length
measurement
accuracy
1.5 m plus 1 % of length
Output power
(nominal)
-24 dBm with EF-TRC
-4 dBm
Output power
stability
4
0.05 dB over 8 hours
0.03 dB over 15 minutes
0.1 dB over 8 hours
0.08 dB over 15 minutes
1. In Auto CertiFiber Pro mode. In Auto SimpliFiber Pro mode: < 4 seconds (2
wavelengths). With the source in continuous-wave mode: < 1 second (1
wavelength).
2. At the output of the EF-TRC.
3. Variations between EF measurement equipment may occur but EF compliance can
be expected with a 95 % confidence factor.
4. At constant temperature, relative to power level after 15 minute warm up.