Certifiber pro olts loss/length specifications – Fluke Networks CertiFiber Pro Users Manual User Manual

Page 402

Advertising
background image

Versiv Cabling Certification Product Family
Technical Reference Handbook

380

CertiFiber Pro OLTS Loss/Length Specifications

Specification

CertiFiber Pro

Multimode Modules

CertiFiber Pro

Singlemode Modules

Testing speeds
(excluding
referencing
times)

Smart Remote mode (2 wavelengths, one direction):  3 s
Far End Source mode

1

(2 wavelengths, one direction): 2 s

Loopback mode (2 wavelengths, one direction):  2 s

Input/output
connectors

Interchangeable connector adapter (LC standard on input,
SC standard on output)

Launch
Condition

Encircled flux compliant to TIA 455-526-14-B, 
ISO/IEC 14763-3, and IEC 61280-4-1

2,3

Fiber types
tested

50/125 µm, 62.5/125 µm
multimode fiber

Singlemode fiber

Source type and
wavelengths

Multimode LED source
850 nm  30 nm
1300 nm  20 nm

Fabry-Perot laser diode
1310 nm  20 nm
1550 nm  30 nm

Maximum
length
measurement

12 km

130 km

Length
measurement
accuracy

 1.5 m plus  1 % of length

Output power
(nominal)

 -24 dBm with EF-TRC

 -4 dBm

Output power
stability

4

 0.05 dB over 8 hours
 0.03 dB over 15 minutes

 0.1 dB over 8 hours
 0.08 dB over 15 minutes

1. In Auto CertiFiber Pro mode. In Auto SimpliFiber Pro mode: < 4 seconds (2

wavelengths). With the source in continuous-wave mode: < 1 second (1
wavelength).

2. At the output of the EF-TRC.
3. Variations between EF measurement equipment may occur but EF compliance can

be expected with a 95 % confidence factor.

4. At constant temperature, relative to power level after 15 minute warm up.

Advertising