OptiFiber Pro OTDR Module Specifications
Multimode
Singlemode
OTDR Port
Cleanable and
Interchangeable
UPC polish
Cleanable and
Interchangeable
UPC polish
Wavelengths
850 nm 10 nm
1300 nm +35 / -15 nm
1310 nm 25 nm
1550 nm 30 nm
Compatible Fiber Types
50/125 µm
62.5/125 µm
multimode fiber
Singlemode fiber
Event Dead Zone
1
850 nm: 0.5 m typical
1300 nm: 0.7 m typical
1310 nm: 0.6 m typical
1550 nm: 0.6 m typical
Attenuation Dead Zone
2
850 nm: 2.2 m typical
1300 nm: 4.5 m typical
1310 nm: 3.6 m typical
1550 nm: 3.7 m typical
1. Measured at 1.5 dB below non-saturating reflection peak with the shortest pulse
width. Reflection peak < -40 dB for multimode and < -50 dB for singlemode.
2. Measured at 0.5 dB deviation from backscatter with the shortest pulse width.
Reflection peak < -40 dB for multimode and < -50 dB for singlemode.