Chapter 15: Custom Media and Test Limits

How to Make a Custom Fiber Test Limit

353

Table 17. Custom Test Limit Settings for Loss/Length Tests

Setting

Description

Length

Enter a maximum length for the link.

Loss Budget

Fixed

: The tester compares the loss of the link to a

fixed value to give a PASS or FAIL result for the loss
test. You enter maximum values of Overall Loss for
each applicable wavelength under Wavelength
specific settings

.

Length Based

: The tester uses values you enter for

Connector

, Splice, and Loss/km and the measured

length of the link to calculate a limit for the loss test.

Loss Type
(for Length Based
Loss Budget

only)

Connector

: Select this if the link uses standard

connectors, such as SC, LC, ST, or FC connectors.
For the Connection Loss (dB), enter the maximum loss
for one connection.
MPO Module

: Select this if the link uses MPO

modules. Connection Loss (dB) changes to MPO
Module Loss (dB)

.

For MPO Module Loss (dB), enter the maximum loss
for one MPO module.

Splice Loss
(for Length Based
Loss Budget

only)

Enter a maximum value for the loss of one splice.

Wavelength
specific settings

For a fixed loss budget, enter maximum values of
Overall Loss

for a link for each applicable

wavelength.
For a length-based loss budget, enter maximum
values of Loss/km for the fiber type for each
applicable wavelength.

-continued-

Advertising