Fluke Networks CertiFiber Pro Users Manual User Manual
Page 384

Versiv Cabling Certification Product Family
Technical Reference Handbook
362
To use an updated main unit to update a remote or another main
unit
1
Turn on both testers and connect the AC adapters to both
testers.
2
Use the USB cable provided to connect the updated main unit
to the remote or to another main. See Figure 134.
3
Follow the instructions shown on the display of the updated
main unit.
Note
If a remote has newer software than the main
unit, the main unit can install the older software
in the remote so that you can use the two units
together. The remote cannot install the newer
software in the main unit.
To update the software in a module
To update the software in a module, attach it to a Versiv unit that
has the latest software. The tester automatically installs the
software in the module.