5. Required Tools and Critical Tool Characteristics

PNEG-1708 GSI Modular Tower Dryer

27

a. Compression channel: Regardless of what leveling tool is used, the proper reference point for

leveling the unload module of the dryer is the Compression Channel and NOT the base/leg
plates on the concrete.

See Figure 5G

for reference.

The Compression Channel is the “ledge” around the unload module of the dryer. Use this as the
reference point for leveling the unit. Do NOT use base plates/feet to determine whether or not unit
is level.

Figure 5G Unload Module with Compression Channel Marked

Compression channel ledge