6 outputs, 1 outputs of the system 182 xt-4, Outputs -1 – YSI DIQ/S 182 XT-4 System 182 XT-4 User Manual
Page 93: Outputs of the system 182 xt-4 -1, He chapter 6 o, Utputs, 6outputs
System 182 XT-4
Outputs
6 - 1
ba76026e01
01/2012
6
Outputs
6.1
Outputs of the system 182 XT-4
The DIQ/S 182 XT-4 has six relay outputs and five current outputs. The
outputs are spread over the two terminal strips as follows (Rx = relay
output, Cy = current output):
Allocation of the outputs
Note
The terminal strips are shown in section 3.14.
Functions for relay
outputs
System monitoring
Sensor monitoring
Limit indicator
Frequency output
Pulse-width output
Sensor controlled
Cleaning
Manual control
Relay outputs can be configured as openers or closers.
Name in the menu
SETTINGS
Front terminal
strip
Rear terminal
strip
DIQ/S182 XT-4 R1
R1
DIQ/S182 XT-4 R2
R2
DIQ/S182 XT-4 R3
R3
DIQ/S182 XT-4 C1
REC C1
DIQ/S182 XT-4 C2
REC C2
DIQ/CR3 R1
R1
DIQ/CR3 R2
R2
DIQ/CR3 R3
R3
DIQ/CR3 C1
REC C1
DIQ/CR3 C2
REC C2
DIQ/CR3 C3
REC C3