15 glossary – Xylem inoLab 7310_7310P WASTEWATER pH METER User Manual

Page 67

Advertising
background image

pH 7310

Glossary

ba75929e03

12/2011

67

15

Glossary

pH/ORP

General information

Asymmetry

see zero point

Electromotive force of

an electrode

The electromotive force U of the combination electrode is the measur-
able electromotive force of an electrode in a solution. It equals the
sum of all the galvanic voltages of the combination electrode. Its
dependency on the pH results in the electrode function, which is char-
acterized by the parameters, slope and zero point.

Junction

The junction is a porous body in the housing wall of reference elec-
trodes or electrolyte bridges. It arranges the electrical contact
between two solutions and makes the electrolyte exchange more dif-
ficult. The expression, junction, is also used for ground or junction-
less transitions.

ORP voltage

The ORP is caused by oxidizing or reducing substances dissolved in
water if these substances become effective on an electrode surface
(e. g. a gold or platinum surface).

pH value

The pH value is a measure of the acidic or basic effect of an aqueous
solution. It corresponds to the negative decadic logarithm of the molal
hydrogen ions activity divided by the unit of the molality. The practical
pH value is the value of a pH measurement.

Potentiometry

Name of a measuring technique. The signal (depending on the mea-
sured parameter) of the electrode is the electrical potential. The elec-
trical current remains constant.

Slope

The slope of a linear calibration function.

Zero point

The zero point of a pH combination electrode is the pH value at which
the electromotive force of the pH combination electrode at a specified
temperature is zero. Normally, this is at 25 °C.

Adjusting

To manipulate a measuring system so that the relevant value (e. g. the
displayed value) differs as little as possible from the correct value or
a value that is regarded as correct, or that the difference remains
within the tolerance.

AutoRange

Name of the automatic selection of the measuring range.

Calibration

Comparing the value from a measuring system (e. g. the displayed
value) to the correct value or a value that is regarded as correct.
Often, this expression is also used when the measuring system is
adjusted at the same time (see adjusting).

Measured parameter

The measured parameter is the physical dimension determined by
measuring, e. g. pH, conductivity or D.O. concentration.

Advertising