Symbol definitions for ip sis commands, Symbol definitions for ip sis commands -19, Preliminar y – Extron Electronics MPX Plus 866 A Rev. B User Manual

Page 103

Advertising
background image

4-19

MPX Plus 866 A Media Presentation Matrix Switcher • SIS Programming and Control

PRELIMINAR

Y

Symbol definitions for IP SIS commands

X3)

= Matrix name

(Up to 240 characters)

N

The following characters are invalid in the name: {space} ~ , @ = ` [ ] { } < > ‘ “ ; : \ | and ?.

X3!

= Default name

Factory default name (model name + last 3 pairs of MAC address)

X3@

= Time and date (set)

In the format: MM/DD/YY•HH:MM:SS where:

MM = month: 01 (January) through 12 (December)

DD = day: 01 through 31

YY = year: 00 through 99

HH = hour: 00 through 24

MM = minutes: 00 through 59

SS = seconds: 00 through 59

X3#

= Time and date (read)

In the format: Day,•DD•Mmm•YYYY•HH:MM:SS where

Day = weekday: Mon through Sun

DD = day: 01 through 31

Mmm = month: Jan through Dec

YYYY = year: 2000 through 2099

HH = hour: 00 through 24

MM = minutes: 00 through 59

SS = seconds: 00 through 59

X3$

= GMT offset

-12.0 through +14.0 (hours and minutes removed from GMT)

X3%

= Daylight Savings Time

0 = Daylight Savings Time off/ignore

1 = Daylight Savings Time on (northern hemisphere)

2 = Daylight Savings Time on (Europe)

3 = Daylight Savings Time on (Brazil)

X3^

= IP address

###.###.###.###

X3&

= Hardware (MAC) address

##-##-##-##-##-##

X3*

= Number of open connections

0 - 255

X3(

= Password

12 alphanumeric characters

N

The following characters are invalid in passwords: {space} ~ , @ = ` [ ] { } < > ‘ “ ; : \ | and ?.

X4)

= Domain name

Standard domain name conventions apply (for example, xxx.com)

N

The following characters are invalid in passwords: {space} ~ , = ` [ ] { } < > ‘ “ ; : \ | and ?

The @ character is only acceptable as the lead-in to the domain name (such as

@extron.com).

X4^

= DHCP

0 = off, 1 = on

X4&

= Port #

01 = rear panel RS-232 Primary port

02 = rear panel RS-232 Secondary port/front panel Cofiguration port

N

The rear panel RS-232 Secondary port (X4& = 02) is active only if the front panel Configuration port is not in use. If a front panel

configuration connection is made, the rear panel RS-232 Secondary port becomes inactive and the front panel Configuration port is
active.

X4*

= Baud rate

9600, 19200, 38400, 115200

X4(

= Parity

O

dd, even, none, mark, space (only first letter required)

X5)

= Data bits

7, 8

X5!

= Stop bits

1, 2

X5@

= Port type

0 = RS-232

1 = RS-422

X5#

= Verbose mode

0 = Clear/none (default for Telnet connection

1 = Verbose mode (default for RS-232 connection)

2 = Tagged responses for queries

3 = Verbose mode and tagged for queries

N

If tagged responses is enabled, all read commands return the constant string and the value as the set command does (for example, the read

matrix name command, ECN}, returns IPN•X3)]).

X5$

= Security level

00 = Anonymous

10 = Extended security levels 1 through 10

11 = User

12 = Administrator

X5%

= RAM status

0 = RAM dirty (needs saving to flash)

1 = RAM has been saved (ok to power off / reset)

X5^

= Port timeout interval (in 10-sec. increments)

1 (= 10 seconds) – 65000 (default is 30 = 300 seconds = 5 minutes)

Advertising