Software operation via serial port, Software operation via ethernet, Ethernet protocol settings – Extron Electronics MPX Plus 866 A Rev. B User Manual

Page 109: Ethernet protocol settings -3, Preliminar y

Advertising
background image

5-3

MPX Plus 866 A Media Presentation Matrix Switcher • Switcher Software

PRELIMINAR

Y

4

.

Follow the on-screen instructions.

By default, the installation of the DSP Configurator program creates a

C:\Program Files\Extron\DSP_Configurator directory, and it places the

following four icons into a group folder named “Extron Electronics\DSP

Configurator”:

DSP Configurator

DSP Configurator Help

Uninstall DSP Configurator

Check for DSP Configurator Updates

By default, the installation of the Matrix Switchers Control Program creates

a C:\Program Files\Extron\Matrix_Switchers directory, and it places the

following four icons into a group folder named “Extron Electronics\Matrix

Switchers”:

MATRIX Switcher+ Control Program

MATRIX Switcher+ Help

Uninstall MATRIX Switcher

Check for Matrix Updates

Software operation via serial port

The MPX Plus switcher can support remote control via either rear panel RS-232

port or the front panel Configuration port. The program can operate at 9600, 19200,

38400, or 115200 baud rates for either port. See “Selecting the RS-232 Primary port’s

baud rate” in chapter 3, “Operation”, to configure the rear panel Remote RS-232

Primary port from the front panel. See the Serial port configuration commands on

page 4-20 to configure any of the serial ports using an SIS command.

Software operation via Ethernet

When a matrix switcher is connected to an Ethernet WAN or LAN, up to 200 users

can operate it, locally or remotely, using the DSP Configurator or the Matrix

Switchers Control Program. See “Ethernet connection”, in chapter 2, “Installation”,

for installation details.
Connection to the switcher via the Ethernet for the Matrix Switchers Control

Program may be password protected. There are two levels of password protection:

administrator and user. Administrators have full access to all switching capabilities

and editing functions. Users can select inputs and outputs, set and recall presets,

and view all settings with the exception of passwords. If the same password or

no password is required for logging on, all personnel log on with administrator

privileges. Fields and functions that exceed user privileges are blocked in the

applicable programs when the operator is logged on as a user.

Ethernet protocol settings

The IP Settings/Options screen of the Matrix Switchers Control Program

(figure 5-26 on page 5-44) provides a location for viewing and, if connected via

the RS-232 link or if logged on via the Ethernet port as an administrator, editing

settings unique to the Ethernet interface. See “IP Settings/Options window” later

in this chapter for more details.

Advertising