4.5.2 Screenshots Parameter

Before using DVR snapshot function, please set the snapshots parameters. It will be related to picture playback effect, snapshot interval and the picture size.

Enter “Main Menu” -> “Record Setup” -> “Screenshot Para.” interface as the right picture:
l Channel No.: Select the channel which you want to set.
l Snapshot type: The snapshot parameters will be active in the selected snapshot type.
l Resolution: Support FD1/CIF (960H/Q960H).
l Image quality: Image quality have 6 levels: Highest, Higher, High, Middle, Low, Lowest.
l Snapshot cycle: Can set 1-5 seconds. l Snapshot pics: 1.

Snapshot type explaining:
l Manual screenshot in channel preview image: Right click mouse in channel preview image,

select “Manual Screenshot” item, then you will snapshot a picture manually.
l Manual snapshot by system: If you open manual snapshot parameter at one certain time,

the system will snapshot until you close the manual snapshot at some certain time.
l Schedule Snapshot: The system will snapshot in a regular time period. Max can set 6 time periods.
l Motion snapshot: Enable “Motion snapshot”. The system will snapshot only when it detect there have motion event.
l Alarm snapshot: Enable “Alarm snapshot”. The system will snapshot only when it detect there have alarm event.

Enter “Main Menu” -> “Record Setup” -> “Advanced” interface as the right picture:
l Record overwrite: Suggest that you can select “Auto”. When HDD is full, it will auto overwrite

the oldest record file. When record overwrite happens, the HDD free capacity is 0%. “Manual” type

is when the HDD is full, the system will show message that if you want to overwrite the oldest record

and the same time the system will stop recording until you agree with the message.
l Maximum days of record/pictures saving: Default is “Unlimited”. If you set max saving days, the data

which is beyond the saving days will be deleted. For example: If you set max saving days is 1 week, when

system time is 8th day, then the record before 1st day will be deleted.

Note: The record file which was set as “Locked” or “Read-Only” cannot be deleted or overwrote.

4.5.3 Advanced