User manual – eLine Technology PRO3 User Manual User Manual

Page 46

Advertising
background image

 

46

User Manual

4.6.2 Sensor

Sensor alarm recording setting steps:

Step1: Enter “Main Menu” -> “Record Setup” -> “Record Para.” interface to set the channel pre-record time and delay-record time.

Step2: Enter “Main Menu” -> “Alarm Setup” -> “Sensor” , then the interface is the right figure above:

Step3: Select Sensor type: Normal on or Normal off.

Step4: Select sensor number.

Step5: Set sensor deploying time (the specific setting please refer to schedule record).

Step6: Linkage setting: Set Trigger Record, Screenshot linkage, Alarm output, Email linkage, PTZ preset point.
l Trigger Record: Select the channel number which you want to set linkage.
l Screenshot linkage: Choose the channel which for screenshot linkage and set the alarm screenshot at screenshot parameter menu.
l Alarm output: If alarm output setting is blue color means it will alarm when have alarm events. If is grey color mean will not alarm output.
l Email linkage: Select “Email linkage” means DVR system can send the alarm information to your email box which have set when sensor alarm happens.
l PTZ preset point: System support the function of dome will turn to preset point when alarm happens. Setting steps as below:

1. Select “PTZ preset point” enter setting interface. Enable “PTZ preset point available”, then set the PTZ preset point. (Note: PTZ preset point value range 1-255, 255 means close.

) After finish setting, save the setting and return to sensor setting interface.

2. Set the COM number, COM device and baud rate in COM Setting interface.

3. Set the PTZ protocol and address code in PTZ Setting interface.

4. Switch the image to which you want to set preset point channel, press “PTZ” button in remote controller

or front panel to enter PTZ control mode. Click “Preset” button, input the preset point which you have set

in step 1. Or you can right click mouse to enter PTZ control mode, then input the preset point, click “Preset”

button to save the setting, at last exit the PTZ control mode.

Enter “Main Menu” -> “Alarm Setup” -> “Alarm Output” interface as the right picture:

You can set alarm during time, audio, buzzer, full screen and alarm output deploying time.
l Alarm during time: Alarm detection time 2~300 seconds. System default as 30 seconds.
l Audio: If you select it, the alarm sound will be send out from the audio output.
l Buzzer: The buzzer in mainboard will beep after have alarm.

4.6.3 Alarm Output

eLineTechnology.com

Advertising