-13-

DIGIT SELECT KEY

VALUE SELECT KEY

MENU KEY

0

Not rate of change

1

Rate x 0.1

2

Rate x 1

3

Rate x 10

4

Rate x 100

5

Rate x 1000

6

Rate x 10000

0

Use setup scaling method

1

Scale by reading input

0

Unlatched

1

Latched

0

Full duplex mode

1

Half duplex mode

0

Linear input

1

Custom curve

2

0

Output is unfiltered

1

Output is filtered

0

Peak of unfiltered signal

1

Peak of filtered signal

0

Batch average, 16 rdgs

1

Display filtered signal

ConFG

Meter Configuration

FiLtr

Filtering

00000

Operates as a rate of change
meter
Extended version only

00000

Selection of scaling by read-
ing input signal or by Setup
selection

00000

Selects between continuous
(unlatched) data or single
value (latched) of RS232 data
when RTS is high or open

00000

RS485 interface operates in
the full duplex or half duplex
mode

00000

Scaling for nonlinear input
Extended version only

00000

Alarm filtering

00000

Peak display filtering

00000

Display filtering