Laurel Electronics LAUREATE SERIES DPM User Manual

Page 18

Advertising
background image

-16-

DIGIT SELECT KEY

VALUE SELECT KEY

MENU KEY

0

0

AL1 Band deviation

AL2 Band deviation

1

AL1 Hysteresis

AL2 Band deviation

2

AL1 Band deviation

AL2 Hysteresis

3

AL1 Hysteresis

AL2 Hysteresis

No deviation or hyster-

esis in menu

After 1 reading

1

After 2 readings

2

After 4 readings

3

After 8 readings

4

After 16 readings

5

After 32 readings

6

After 64 readings

7

After 128 readings

ALSEt

(continued)

Alarm Operation Setup

4

00000

dEU1H

Amount of deviation or
hysteresis - Alarm 1
(Only enabled if relay output
is installed).

00000

Selection of Hysteresis mode
or Band Deviation mode of
alarms.

Number of readings in the
alarm zone to cause an alarm

00000

00000

00000

00000

When the deviation value is
>0, the alarms operate above
and below setpoint by the value
entered.

Select 0 through 9 for flashing
digit.

dEU2b

Amount of deviation or
hysteresis - Alarm 2
(Only enabled if relay output
is installed).

00000

00000

00000

00000

00000

When the deviation value is
>0, the alarms operate above
and below setpoint by the value
entered.

Select 0 through 9 for flashing
digit.

An Set

Setup of analog output.
(Only enabled if analog output
board is installed).

00

0

1

00

0

1

00000

Calibrated output is current or
voltage.

Current output

Voltage output

Analog output filtering

.

Analog output unfiltered

Analog output filtered

Advertising