DIGIT SELECT KEY
VALUE SELECT KEY
MENU KEY
0
0
AL1 Band deviation
AL2 Band deviation
1
AL1 Hysteresis
AL2 Band deviation
2
AL1 Band deviation
AL2 Hysteresis
3
AL1 Hysteresis
AL2 Hysteresis
No deviation or hyster-
esis in menu
After 1 reading
1
After 2 readings
2
After 4 readings
3
After 8 readings
4
After 16 readings
5
After 32 readings
6
After 64 readings
7
After 128 readings
ALSEt
(continued)
Alarm Operation Setup
4
00000
dEU1H
Amount of deviation or
hysteresis - Alarm 1
(Only enabled if relay output
is installed).
00000
Selection of Hysteresis mode
or Band Deviation mode of
alarms.
Number of readings in the
alarm zone to cause an alarm
00000
00000
00000
00000
When the deviation value is
>0, the alarms operate above
and below setpoint by the value
entered.
Select 0 through 9 for flashing
digit.
dEU2b
Amount of deviation or
hysteresis - Alarm 2
(Only enabled if relay output
is installed).
00000
00000
00000
00000
00000
When the deviation value is
>0, the alarms operate above
and below setpoint by the value
entered.
Select 0 through 9 for flashing
digit.
An Set
Setup of analog output.
(Only enabled if analog output
board is installed).
00
0
1
00
0
1
00000
Calibrated output is current or
voltage.
Current output
Voltage output
Analog output filtering
.
Analog output unfiltered
Analog output filtered