Ordering guide – Laurel Electronics LAUREATE SERIES DPM User Manual

Page 2

Advertising
background image

ORDERING GUIDE

L .... Laureate series meter with

screw terminal connectors.

Display Color

1 ............... DPM with green LED
2 ................... DPM with red LED
3 ...... Extended DPM/green LED
4 ......... Extended DPM/red LED

Note: Extended versions add rate

of change and linearization of
non-linear input signal capabili-
ties. Not available for thermo-
couple or RTD inputs

Power

0 ........................... 85 to 264Vac,

90 to 370Vdc

1 ..............................9 to 37 Vdc,

8 to 28 Vac

Setpoint Output

0 ........................................ None
1 ...................... Dual 10 A relays
2 ..................... Solid state relays

Analog Output

0 ........................................ None
1 .............................. 0 to 20 mA,

0 to 10 Vdc

Digital Interface

0 ........................................ None
1 ..................................... RS-232
2 ..................................... RS-485
3 ......................................... BCD

Input Type

DC Volts

DCV1 ................ 200.00 mV
DCV2 ................... 2.0000 V
DCV3 ................... 20.000 V
DCV4 ................... 200.00 V
DCV5 ..................... 660.0 V

DC Amperes

DCA1 ................ 2.0000 mA
DCA2 ................ 20.000 mA
DCA3 ................ 200.00 mA
DCA4 ..................... 5.000 A

100 Ohm Platinum RTD’s

P385C ......... -202 to 850°C
P385F ......... -331 to 1562°F
P392C ......... -202 to 850°C
P392F ......... -331 to 1562°F

Thermocouples

JC ................ -210 to 760°C
JF ............... -347 to 1400°F
KC ............. -244 to 1372°C
KF .............. -408 to 2501°F
TC ............... -257 to 400°C
TF ................. -430 to 752°F
EC ............. -240 to 1000°C
EF ............... -400 to 1830°F
NC ............. -244 to 1372°C
NF .............. -408 to 2501°F
SC ............... -46 to 1768°C
SF ................. -51 to 3214°F
RC ............... -45 to 1768°C
RF ................ -49 to 3213°F

Process Signals
(4 to 20 mA, 0 to 5 V, etc.)

P ... 4 to 20 mA=0 to 100.00
P1 ............. Custom Scaling

Specify minimum input signal
and displayed reading and
maximum input signal and dis-
played reading.

Strain Gauges, Potentio-
meters
(4-wire ratio)

SG . 0 to 200mV=0 to 100.00
SG1 ............ Custom Scaling

Specify minimum input signal
and displayed reading and
maximum input signal and dis-
played reading. Full scale in-
put 200mV to 20V. 10 Vdc
excitation.

RMS Volts

RMV1 ................. 200.00 mV
RMV2 .................... 2.0000 V
RMV3 .................... 20.000 V
RMV4 .................... 200.00 V
RMV5 ...................... 660.0 V

RMS Amperes

RMA1 ................. 2.0000 mA
RMA2 ................. 20.000 mA
RMA3 ................. 200.00 mA
RMA4 ...................... 5.000 A

Load Cells (6-wire ratio)

WM1 ..... -99,999 to +99,999.
Specify minimum input signal
and displayed reading and
maximum input signal and dis-
played reading. Full scale in-
put 20 mV to 500 mV. 10 Vdc
excitation.

Advertising