21. 2 BCD OUTPUT LEVELS

The BCD option provides isolated, buffered, stored, 3-state parallel outputs that are selectable
for either 0 to 5V logic levels (LSTTL, CMOS compatible) or 0 to 15Vdc. Selection jumpers are
located on the BCD board. BCD outputs are positive true. Polarity bit is positive true for +sign.

LOGIC LEVEL

JUMPER REQUIRED

0 to 5Vdc

b

0 to 15Vdc

a

21. 3 BCD CONTROL SIGNALS

Enable

Logical 0 - All outputs go to the high impedance state
Logical 1 - BCD information is available at outputs.

BCD Hold

Logical 0 - BCD from last update prior to BCD Hold going low is stored
Logical 1- BCD information updates at selected rate.

Data Ready Logical 0 - BCD outputs are valid

Logical 1 - BCD outputs are not valid

VALUE SELECT KEY

Press the

key until SEr

1 (Serial interface setup 1) is
displayed.

Press

to display status.

Press

again to select

digit. Selected digit will flash.
Digit 3: Output filtering

Digit 5: Output update rate

Press to select value for
flashing digit

3: "0"-Send unfiltered signal
"1"-Send filtered signal
5: "0"-Line frequency
"1" to "9"
- Batch display rate (3.5/
sec) to Batch display rate
/ 256 (1 every 15 min.)

1 2 3 4 5