Laurel Electronics LAUREATE SERIES DPM User Manual

Page 46

Advertising
background image

Span Tempco ....................................................................................... 0.003% of reading/°C

Load Cell Meter only .................................................................. 0.0015% of reading/°C

Zero Tempco ........................................................................................................... 0.2 uV/°C
Reference Junction ................................................................................. 0.03 degree/degree

POWER SUPPLIES

Input Voltage (std) .................................................................... 85 to 264 Vac, 90 to 370 Vdc
Input Voltage (opt) ............................................................................ 8 to 28 Vac, 9 to 37 Vdc
Frequency ............................................................................................. DC and 47 to 440 Hz
Consumption .................................................................................................. 5.3 Watts max.

Excitation Power Supplies
Outputs ............................................................................................. 5 Vdc, 5%, 100 mA max

10 Vdc, 5%, 120 mA max.

24 Vdc, 5%, 40 mA max.

Ripple .............................................................................................................. 100 mVp max.
Isolation ............................................. Safety-rated to 250Vac, 4.2kVp per High Voltage Test

DUAL CONTROLLER OPTION

Basic

Power ............................................................................................... Provided by basic meter
Update Rate ............................................................................... 56/s at 60 Hz, 47/s at 50 Hz
Setup ....................................................................... setpoint values may be entered by front

panel pushbuttons or via RS-232 or RS-485

Lockouts ........................................... Front panel pushbuttons control display and change of

setpoints, only control display of setpoints, or are disabled.

Output Operation .................................. either output may be set to operate above, below or

around the setpoint, latching or non-latching or output disabled

Filtering ................................................................ comparison to the setpoints may be either

from the filtered or unfiltered input signal

Time Delay .................................................................. selectable time delay of output status

change of 1 to 128 readings

Hysteresis ................................................................... selectable from 0 to +/- 99,999 counts

Alarm Status Indicators
Type ............................................................................................................. 2 red LED lamps

Relay Output

Contact Rating...................................................................... 10 A @ 240 Vac, 8 A @ 24 Vdc
Safety Certification ................................................................................... VDE, UL, and CSA

-44-