Chapter 3 Multi-Mon Display Operations

Menu Operations

30

Multi-Mon

Multiple Circuit Energy Monitor

2. To link a current input to a submeter, select the desired input ID with the

UP/DOWN buttons.

3. To change the CT primary rating, highlight desired digits by briefly

pressing the SELECT button, then adjust them to the desired value with
the UP/DOWN buttons.

4. Press the ENTER button to store your selection. You return to the

parameter list to select another parameter or return to the main menu.

To exit the menu, highlight the menu name (upper-left item) with the
SELECT button, and then press the ENTER button.

The following table lists available options.

Label

Label

Label

Label

Parameter

Parameter

Parameter

Parameter

Options

Options

Options

Options

Default

Default

Default

Default

Description

Description

Description

Description

Phase L1

Phase L1

Phase L1

Phase L1
Phase L2

Phase L2

Phase L2

Phase L2
Phase L3

Phase L3

Phase L3

Phase L3

Phase current
input terminal
number

I1–I36,
None = not
connected

See
note

1

Links a current input terminal
to the corresponding
submeter’s phase voltage
input V1, V2 or V3

CT

CT

CT

CT

CT primary
current

2

1-10000 A

50 A

Specifies the primary rating of
the submeter current
transformers

1

The device is pre-configured for twelve three-phase submeters.

2

Specify the CT ratings assuming a ×200% device inputs overrange. The

device inputs are preset for 100A current transformers with a 50A primary
rating.

Reset

Reset

Reset

Reset

This menu allows you to reset maximum demands in each submeter and to
clear the device diagnostics.

To enter the menu, select the Reset entry from the main menu, and then
press the ENTER button.

To reset the desired registers:

1. Highlight the upper-right item by briefly pressing the SELECT button.

2. Select the submeter you are going to clear with the UP/DOWN buttons.

3. Highlight the lower-left item by pressing the SELECT button.

4. Scroll through the list with the UP/DOWN buttons until the desired entry

appears.

5. Press the SELECT button to highlight the lower-right item.

6. Press and hold the ENTER button for 5 seconds. The “Do” entry is

replaced with “Done” showing the operation is complete.

To exit the menu, highlight the menu name (upper-left item) with the
SELECT button, and then press the ENTER button.

The following table lists reset options.

Label

Label

Label

Label

Parameter

Parameter

Parameter

Parameter

Diag.

Diag.

Diag.

Diag.

Clears device diagnostics status

Pow.Dmd

Pow.Dmd

Pow.Dmd

Pow.Dmd

Clears maximum power demands

Amp.Dmd

Amp.Dmd

Amp.Dmd

Amp.Dmd

Clears maximum ampere and volt demands

Max.Dmd

Max.Dmd

Max.Dmd

Max.Dmd

Clears all maximum demands

Reset

SM 1

Diag.

Do

Reset

SM 4

Diag.

Do

Reset

SM 4

Diag.

Do

Reset

SM 4

Pow.Dmd

Do

ENTER

Reset

SM 4

Pow.Dmd

Do

SELECT

SELECT

Reset

SM 4

Pow.Dmd

Done

SELECT

SubMeter SM 4

Phase L1

I1

SubMeter SM 4

Phase L1 I10

ENTER

SubMeter SM 4

Phase L1 10

Advertising
This manual is related to the following products: