Appendix i: fieldbus interface reference data, A. introduction, B. hardware specifications – Fairbanks FB2550 SERIES User Manual
Page 159

07/2012
159
51254 Rev. 3
Appendix I: Fieldbus Interface Reference Data
A. INTRODUCTION
The Fieldbus interface(s) support a bi-directional communication capability for the
FB2550 instrument.
The FB2550 Interface supports a variety of industrial protocols.
– These include Profibus, DeviceNet, ControlNet and Modbus-RTU.
Even though the FB2550 can be configured with up to eight (8) scales, the
Fieldbus applications are limited to four (4) scales.
B. HARDWARE SPECIFICATIONS
Power
9-40 VDC (24 VDC Nominal)
Power Consumption
300 mA typical 800 mA max (@24 VDC)
Interface connections
Field bus as selected, serial channel
LEDs/indicators
Power, Network connection
Operating Temperature
0 to 70 C
Storage Temperature
-40 to 85 C
Operating humidity
90% non-condensing
Enclosure rating
None
Mounting options
Thru holes
Others
RoHS
Physical Dimensions
4.24 inches x 3.20 inches
Approval
CE