Printer setup and programming, Oki ml420 printer settings – Fairbanks FB2550 SERIES User Manual
Page 61

Section 5: Input/ Output
07/2012
61
51254 Rev. 3
5.4. PRINTER SETUP AND PROGRAMMING
NOTE:
The standard default configuration on the COM Ports to all printers is set at
9600 Baud, 8 data bits, No Parity, and 1 stop bit.
5.4.1. OKI ML420 PRINTER SETTINGS
•
For FB2550 Instrument Desktop and NEMA 4X SERIAL communications, use
cable
25932
or
14807
•
For USB input, use cable
29827C
.
•
All printer settings apply to both the Serial and USB models.
BAUD
9600
&*PARITY
No
DATA BITS
8
STOP BIT
1
CABLE 14807 WIRING for COM Ports 1-3
DB-9 Instrument
Description
DB-25 Printer
3
Transmit (Tx)
3
2
Receive (Rx)
2
5
Ground (GND)
7
CABLE 29827C WIRING for Serial Expansion Module *
RS232
Port 1: COM XX
RS232
Port 2: COM XX
RS232
Port 3: COM XX
Description
DB-25 Printer
TB1a-3
TB1b-5
TB1d-2
Transmit (Tx)
3
TB1a-2
TB1c-1
TB1d-3
Receive (Rx)
2
TB1a-5
TB1c-2
TB1d-4
Ground (GND)
7
SEL
EXIT
POWER
SHIFT
ALARM
LF
GROUP
Micro Feed
Down
FF/LOAD
Micro Feed
Up
ITEM
MENU
TEAR
SET
PARK
QUIET
TOF
SEL
MENU