5.8.3. METHOD 1 – PRE-CONFIGURED OUTPUT,

CONTINUED

6. Select the

LOAD

button.

– This selection will bring up a menu a

five (5) pre-configured outputs.

7. When configuring an output data

string, the Fairbanks’ FB2550 has
seven (7) commonly used pre-
configured outputs.

8. Select the correct data string type.

Displayed below are the data string protocols.

*

Fairbanks

<STX><A><B><C><GGGGGG><TTTTTT><CR>

Toledo

<STX><A><B><C><GGGGGG><TTTTTT><CR>

Cardinal

<CR><P><WWWWWW><m><SP><U><SP><g><SP><SP><ETX>

Weightronix

< ><M><WWWWWW>< ><U><CR><LF>

Condec

<STX><P><WWWWWW><U><G><M><CR>

DT7000 Anybus

<STX><SW0><SW1><SW2><UD><GW><TW>NW><SP1><SP2><FR><UD><CRC><XCH>

SMA Protocol

<LF> <S> <R> <N> <M> <F> <XXXXXX.XXX> <UUU> <CR>

*

See

Appendix II: Data Output

for further information.