Fairbanks FB2550 SERIES User Manual
Page 87

Section 5: Input/ Output
07/2012
87
51254 Rev. 3
5.7.3. SERIAL 20 MA CONFIGURATION (SERIAL
EXPANSION BOARD)
1. Select
LOGIN
.
2. Enter the Supervisor Password or
Service Password.
3. Select the
CONFIGURATION
MENU
.
4. Press PAGE FORWARD once.
5. Select
REMOTE DISPLAY
.
6. Touch the data box on the screen to
the right of
COM PORT:
, selecting
the desired COM port.
7. Select the
DISPLAY MODE
button,
selecting the desired mode required
from the menu list.
– The menu choices are Continuous
Display or Display on Print.
8. Touch the data box on the screen to the right of
OUTPUT TYPE
:, then
select the desired type required from the menu list.
– The types are Gross Wt, Net Wt, or Ticket Number.
9. Touch the data box on the screen to the right of
OUTPUT SCALE:,
then select the desired scale required from the menu list.
– The scales choices are All, Active or an individual scale.
– It is recommended to leave the settings for baud, parity, and etc. as shown in
the images in steps 3 and 4.