Method 2 - customizing data strings, continued – Fairbanks FB2550 SERIES User Manual

Page 98

Advertising
background image

Section 5: Input/ Output

07/2012

98

51254 Rev. 3

5.8.4. METHOD 2 - CUSTOMIZING DATA STRINGS,

CONTINUED

When configuring an output data string, the Fairbanks’ FB2550 has seven (7)
commonly used pre-configured outputs.

6. Select the correct data string type.

Displayed below are the data string protocols* .

Fairbanks

<STX><A><B><C><GGGGGG><TTTTTT><CR>

Toledo

<STX><A><B><C><GGGGGG><TTTTTT><CR>

Cardinal

<CR><P><WWWWWW><m><SP><U><SP><g><SP><SP><ETX>

Weightronix

< ><M><WWWWWW>< ><U><CR><LF>

Condec

<STX><P><WWWWWW><U><G><M><CR>

DT7000 Anybus

<STX><SW0><SW1><SW2><UD><GW><TW>NW><SP1><SP2><FR><UD><CRC><XCH>

SMA Protocol

<LF> <S> <R> <N> <M> <F> <XXXXXX.XXX> <UUU> <CR>

* See Appendix II: Data Output for further information.

NOTE :

In the images shown,

Configure COM1

was selected.

Advertising