Method 2 - customizing data strings, continued – Fairbanks FB2550 SERIES User Manual
Page 98

Section 5: Input/ Output
07/2012
98
51254 Rev. 3
5.8.4. METHOD 2 - CUSTOMIZING DATA STRINGS,
CONTINUED
When configuring an output data string, the Fairbanks’ FB2550 has seven (7)
commonly used pre-configured outputs.
6. Select the correct data string type.
Displayed below are the data string protocols* .
Fairbanks
<STX><A><B><C><GGGGGG><TTTTTT><CR>
Toledo
<STX><A><B><C><GGGGGG><TTTTTT><CR>
Cardinal
<CR><P><WWWWWW><m><SP><U><SP><g><SP><SP><ETX>
Weightronix
< ><M><WWWWWW>< ><U><CR><LF>
Condec
<STX><P><WWWWWW><U><G><M><CR>
DT7000 Anybus
<STX><SW0><SW1><SW2><UD><GW><TW>NW><SP1><SP2><FR><UD><CRC><XCH>
SMA Protocol
<LF> <S> <R> <N> <M> <F> <XXXXXX.XXX> <UUU> <CR>
* See Appendix II: Data Output for further information.
NOTE :
In the images shown,
Configure COM1