E. status/command word bit usage, continued – Fairbanks FB2550 SERIES User Manual
Page 170

Section 9 Network Application Configuration
07/2012
170
51254 Rev. 3
E. STATUS/COMMAND WORD BIT USAGE, CONTINUED
SCALE ID
WORD 0
BITS 0,1,2
Command:
Changes Instrument display to applicable scale.
Status:
Value is the scale id if the scale is selected, from instrument
keyboard or fieldbus, else the value is zero.
MOTION
WORD 0
BIT 3
Command:
Not applicable.
Status:
Indicates that the scale senses motion.
OVER CAPACITY
WORD 0 BIT 4
Command: Not applicable.
Status:
Indicates that the scale is at 105% of capacity. If this condition is true
the gross weight is sent to the fieldbus as the scale capacity.
WITHIN 2% CAPACITY
WORD 0
BIT 5
Command: Not applicable.
Status:
Scale is within a range of +/- 2% of capacity and zero.
ENABLE TARE
WORD 0
BIT 6
Command: Enable keyboard tare or auto tare weight.
Status:
Tare weight enabled.
DISABLE TARE
WORD 0
BIT 7
Command: Disable keyboard tare and auto tare weight.
Status:
Tare weight disabled.
LB WEIGHT UNITS
WORD 0
BIT 8
Command: Switch scale to lb units.
Status:
Scale is indicating in lb units.