Section 9 Network Application Configuration

07/2012

161

51254 Rev. 3

C. SOFTWARE SPECIFICATIONS, CONTINUED

NOTE WEIGHT VALUES

sent over the Serial Channel will be represented in the

field bus registers based on the settings of

bits 14

and

15

in

Status Word 0

.

– If the data is set to be a 16 bit or 32 bit integer, then the register value will

contain the integer value and the host must multiply this by the scale factor to
get the actual weight.

– If it is set to be a 16 bit integer, and the integer value is greater then 65535, a

value of

0

is placed in the register.

– If the data is set to be

FLOATING POINT

, then the gateway will multiply

the integer value received by the scale factor, and place the resulting 32 bit
floating point value in the register.

In this case the host does not use the scale factor to interpret the value.

INPUT

DATA FORMAT FROM GATEWAY

The Gateway will send a string to the Serial Port reflecting data from the field bus.

The following is the definition of the serial string for one (1) scale.

– The scale ID in the field bus register for Command word 0 for a scale must be

set to the correct value (1-4) before data for that scale will be sent over the
serial channel.

– If the scale ID is set to the correct value, any time any data for this scale

changes the data will be sent out the serial channel.

– Command word data is sent as binary values MSB first over the serial

channel.

– Weight data is sent as six (6) characters representing a six (6) digit decimal

value (

000000 – 999999

).

– This decimal value represents the weight multiplied by the scale factor listed in

command/status word 1 bits 0-2

.

– The serial string is a fixed length of 105 bytes.