3.5. PRECAUTIONS

3.5.1. Welding

If arc welding or cutting is required during any stages of weighbridge and deck

installation, prevent currents from damaging the Load Cells.

The load cell cable must be disconnected.

Removal of the load cells is recommended.

The load cells cable terminations must not be allowed to touch any part of the

weighbridge, pit steel or each other. Insulate each cable lead.

The load cell cables should be coiled up and kept as far as possible from any

steel.

The arc welder ground connection should be made as close as possible to the

weld location.

The arc welder ground must be connected so that currents DO NOT pass through

the load cell(s).

Do not use higher welding current than absolutely necessary.

Protect the load cells from the heating and splattering effects of welding.