SECTION 5: ELECTRICAL INSTALLATION

5.1. WIRING INFORMATION

ALL wiring cable

MUST be a minimum of

18 AWG, with individually

shielded pairs

.

Three (3) pair cable.
─ Use Fairbanks part number

17246

, or an equivalent.

5.1.1. Maximum Cable Lengths

No. of

LOAD CELLS
1000 Ohm Cells

Maximum Cable Lengths for

INDICATOR-TO-POWER SUPPLY

1-10

Up to 1800 feet

12

Up to 1150 feet

14

Up to 800 feet

16

Up to 575 feet

**

See

Appendix I

for the complete wiring charts of the indicator,

Power Supply (

24720

) and the Smart Sectional Controllers (

26168

).

5.2. ELECTRONIC COMPONENT CARE

Most of the electronic equipment consists of printed

circuit assemblies, which

must be installed using

ESD

handling procedures

.

All electronic and mechanical adjustments are

considered to be part of the installation, and are

included in the installation charge(s).

The AC receptacle/outlet must be located near the

Indicator and easily accessible.

Electrical connections other than those specified may

not be performed.

The load cells are calibrated with the cable attached,

and therefore

the cable should NOT be cut.