Section 5: Electrical Installation

12/12

44

51193 Revision 5

5.7. GROUNDING THE SCALE, CONTINUED

The 117 VAC SVP Unit connects to a ground at the instrument’s incoming

power outlet.
─ Use a voltmeter to test the electrical power source available.
─ The Neutral-to-Ground voltage level must be 0.2 VAC or less.








5.8. INDICATOR AND ACCESSORIES. TEST AND CALIBRATION

Use the correct indicator manual(s) to calibrate and test the scale. Also use the

correct accessory manual(s) for proper setup and testing of their functionality and

operation.



C A U T I O N

Proper grounding is

REQUIRED

so the Surge Voltage Protection (SVP) adequately protects the scale!