1.3. COMPONENT DESCRIPTIONS, CONTINUED

1.3.3. Scale Pit

The scale pit is constructed of reinforced

concrete as detailed on the

Certified

Drawing Specifications.

The Tundra Scale requires a four foot

(4’) or deeper foundation.
─ Some states require a minimum of

four feet (48”) pit depth. Consult

with the local W&M for specifics in

your area.

The pit includes correctly positioned

piers with level surfaces for RC type

load cell base plates.

The ground rod(s) should be installed

before the pit floor is poured.

This System uses Intalogix™

Technology,

and requires two (2) pit ground rods.

1.3.4. Smart Sectional Controllers (SSCs)

The Smart Sectional Controllers (SSCs) used on Intalogix

Applications

are mounted

at each section using the supplied self-tapping screws and should be placed on the

cross members at installation.

Each Sectional Controller has four (4) water-tight gland bushings for cables.

The Pit Power Supply(ies) are mounted in the same manor.