Rc load cell wiring, Appendix i – Fairbanks Tundra Series Truck Scale User Manual
Page 40
Section 5: Electrical Installation
12/12
40
51193 Revision 5
5.4. SMART SECTIONAL CONTROLLER (SSC) TO LOAD CELL WIRING
Follow these steps to wire the Sectional Controller
1. Remove the nylon plug from each load cell glands being used.
2. Feed each load cell cable through the appropriate gland in the box.
3. Wire all the cells into each sections Sectional Controller.
4. Also use the appropriate instrument manual for correct procedure.
Drain wires connect to ground lug on the Sectional Controller exterior.
Pull the load cell cables into the Sectional Controller Box 1 (SSC1).
─ The ODD numbered cell is always wired to
TB1
.
─ The EVEN numbered cell is always wired to
TB2
.
─
Wire all the Smart Sectional Controllers (SSCs) and load cells as shown in
Appendix I
.
─ Load cell 'drain' wires connect to ground lug on the
Sectional Controller
Box exterior.
5.4.1. RC Load Cell Wiring
Terminal
Color
Description
1
Black
(─) Excitation
2
Green
(+) Excitation
6
Yellow
Shield
7
White
(+) Signal
8
Red
(─) Signal