Section 5: Electrical Installation

12/12

43

51193 Revision 5

5.7. GROUNDING THE SCALE

Intalogix

Technology systems requires two (2) ground rods in the pit for proper

connection.

Pit power supply connects to one ground rod, and the weighbridge

connects the other one.

For accurate operation and protection against damage from lightning strikes,

all of the components of the system must be properly grounded.

Use the following guidelines to correctly ground the system:

Use 8 AWG or larger wire, or braided ground straps.

All ground connections should be two feet (2’) or less, or as conditions warrant

as short as possible.

The SSCs and PPSs enclosures attach connections to the weighbridge. The

weighbridge is then connected to a pit ground rod.

The insulated WHITE WIRE from the PPS connects directly to the separate

ground rod,

and not to the same rod as the weighbridge.