Section 5: Electrical Installation
12/12
37
51193 Revision 5
5.2.1. Protection Against Hostile Environments
Tundra Scales
provide protection from moisture.
•
The load cells are calibrated with the cable fully attached.
•
The cable connects directly to the Sectional Controller through a sealed
bushing.
─ Tightened the bushings with pliers to keep water/moisture out of the box.
The load cell cable should NEVER be cut.
Add a
"drip loop"
at the load cell or box entry location for all
cabling.
─ This helps prevent water entry.
Pull any free cables and wires together tightly, twist a hoop in
the cables, fastening them with a zip-tie below and away from
all electronic components and off the ground.
C A U T I O N
Surge voltage protection installation is effective
ONLY when an adequate ground(s) is provided.