Vector Solo 65kV Applicator - Installation

INSTALLATION

Air Hose

13

Fluid Hose Recommendation

Ransburg recommends using a 79548 Fluid Hose

Assembly. This assembly is made to specifically

fit the fluid fitting size engineered into the applica-

tor. This hose is available from your authorized

Ransburg distributor. Available hose lengths are

listed in "Accessories" in the "Parts Identification"

section of this manual.

†

Any user installed fluid hose used must

be rated for 100 psig (6.9 bar) working

pressure minimum.

C A U T I O N

!

Filters

1. Install an air filter assembly on the outlet of the

main air regulator. The filter should be 5 micron

with a maximum working pressure of at least 100

psig (6.9 bar). For Class 3 air quality, which is a

5 micron size and has a dew point of -4F (-20C),

the relative humidity (RH) of the air should be 5%.

Screw the fitting into the filter inlet. The filter MUST

be installed with the arrow pointing in the direction

of flow. (Refer to the appropriate Filter Assembly

manual for Installation Instructions.)

2. Ransburg recommends that a fluid filter be in-

stalled at the output of the fluid supply (pressure

pot, pump, circulating system, etc.). It is the end

user's responsibility to install the proper filter that

meets their system's requirements.

79965 SOLO 65KV

SOLVENTBORNE

INSTALLATION

†

The user

MUST read and be familiar

with the "Safety" section of this manual.

†

This hand held device is intended to be

used by trained personnel ONLY.

†

This manual

MUST be read and thor-

oughly understood by

ALL personnel who

operate, clean, or maintain this equipment!

Special care should be taken to ensure that

the warnings and requirements for operat-

ing and servicing safely are followed. The

user should be aware of and adhere to

ALL

local building and fire codes and ordinanc-

es as well as NFPA, OSHA, and all related

country safety codes prior to installing, op-

erating, and/or servicing this equipment.

†

Personnel

MUST be GROUNDED to

prevent a shock or spark during electrostat-

ic operation.

†

Install and route the hoses so they are

NOT exposed to temperatures in excess of

120° F and so that all hose bends are

NO

LESS than a 6-inch (15cm) radius. Fail-

ure to comply with these parameters could

cause equipment malfunction that might

create

HAZARDOUS CONDITIONS!

W A R N I N G

!

†

For proper safe function of the applica-

tor, the 79727-XX Air Hose Assembly must

be used (either standard or quick discon-

nect style).

W A R N I N G

!

AH-08-02.6