The 79870 Test and Maintenance Kit allows the

user to determine the inlet pressure at the base

(handle) of the Vector Solo hand-held applicators.

The Test and Maintenance Kit also allows the user

to test the 79835 Power Module Assembly on the

Vector Solo applicator.

The procedure to test the inlet pressure at the

base (handle) of the Vector Solo applicator is as

follows (see Figures 63 and 64):

1. Connect the left-hand fitting of the 79727 Air

Hose to the male inlet of the Test and Maintenance

Kit.

2. Connect the 6" air hose assembly between the

brass tee fitting and the gun air inlet.

3. Connect the other end of the air hose to the

regulated air supply.

4. Turn on main air. Trigger the applicator with kV

switch on high (down position). Read the pressure

at the 100 psi pressure gauge. This pressure should

be at least 40 psi with air flowing for proper

Figure 64: Testing the Pressure at the Base

(Handle) of the Applicator

1