Air cap, Ransburg, Vector solo 65kv applicator - maintenance – Ransburg Vector Solo 65KV 79965 Solventborne RS70-AS User Manual

Page 27: Removal, Cleaning and inspection, Reinstall

Advertising
background image

Vector Solo 65kV Applicator - Maintenance

23

AH-08-02.6

1. Remove applicator from the worksite after fol-

lowing the "Flush Procedure".

2. Remove fluid hose at base of applicator.

Figure 16: Counter-Clockwise to Remove

Fluid Hose

Figure 17: Clockwise to Remove Air Hose

AIR CAP

Removal

1. While holding the barrel with one hand, loosen

the retaining nut using the other hand.

2. Unscrew the retaining nut completely and

remove the air cap.

Figure 18: Air Cap Removal

Cleaning and Inspection

1. Use a suitable solvent to clean the air cap.

(Refer to "Suitable Solvents for Cleaning Vector

Solo Applicators" in the "Maintenance" section.)

2. Examine the air cap for damage to the air

horns, face, and any air passages. If any of these

areas are damaged or worn, the air cap should

be replaced.

Reinstall

1. Check the fluid nozzle to ensure that it is tightly

screwed into the barrel.

2. Place the air cap over the electrode wire of the

needle/electrode and set it onto the fluid nozzle.

3. Place the retaining nut over the air cap and

begin screwing it onto the barrel.

4. Before securing the retainer nut to the barrel,

position the air cap for the desired spray pattern.

†

Ensure all pressure has been bled from

the fluid and air line prior to disconnection.

W A R N I N G

!

3. Remove air hose at base of applicator.

C C W

C W

C W

C C W

Ransburg

Advertising