31

AH-08-02.6

2. Tighten rear nut using Special Wrench 79854-

00. Tighten until drag is felt on the shaft when it

is pushed back and forth.

Figure 43: Adjustable Needle Shaft

Reinstall Needle Shaft / Barrel

1. Push needle shaft assembly straight into the

barrel. Apply LSCH0009-00 Dielectric Grease.

Figure 42: Needle Shaft Replacement

Figure 45: Power Module Removal

3. Reinstall cascade.

4. Reinstall barrel to handle.

Power Module Removal

1. Remove the fluid line

Figure 44: Fluid Line Removal

†

Be generous with the dielectric grease

when applying it to the packing tube and

needle shaft. This helps to remove air

voids from this chamber.

DO NOT apply

so much grease that it creates an air lock

during assembly of the applicator.

NOTE

2. Remove three (3) bolts using a 3mm Allen

wrench.

5. With your finger, wipe the excess grease from

both ends of the packing tube. Using the excess

grease, apply a thin film to the outer surface of

the packing tube and to the external o-ring on the

cartridge seal.

6. Apply a light film of dielectric grease to the seal

retainer o-ring and install it into the external groove.