Vector Solo 65kV Applicator - Maintenance

35

AH-08-02.6

3. Install the 1/4 module into the 3/4 module and

tighten the two (2) screws.

Figure 61: Module Assembly

4. Install power module to handle and tighten three

(3) screws. Reinstall the fluid line and torque fluid

tube fittings to 40-45 lbs-in.

3. Remove the 1/4 module from the 3/4 module.

Pull the fluid fitting out.

Figure 58: Fluid Fitting Removal

2. Install the fluid fitting.

Figure 60: Fluid Fitting Replacement

Figure 59: Ground Clip Replacement

Fitting Replacement

1. Ensure the ground clip is properly installed.

Tabs must be touching the air and fluid fitting.

Figure 62: Power Module Assembly

†

The ground clip must be properly

installed such that it touches both the air

and fluid fitting.