Needle / electrode, Ransburg, Vector solo 65kv applicator - maintenance – Ransburg Vector Solo 65KV 79965 Solventborne RS70-AS User Manual

Page 29: Reinstall, Removal, Cleaning and inspection

Advertising
background image

Vector Solo 65kV Applicator - Maintenance

25

AH-08-02.6

Reinstall

1. Check the electrode tightness on the needle

shaft. If it is loose, tighten it (refer to "Needle/

Electrode" in the "Maintenance" section).

2. With the applicator trigger actuated, place the

fluid nozzle over the needle/electrode and screw

it into the barrel by hand.

3. Tighten it using the Special Multi-Purpose

Wrench 79854-00 with 3/8" square. Torque to 40-

45 lbs. - in. (4.5 - 5.1 Nm). An alternate method (if

no torque wrench is available) is to hand tighten,

then tighten an additional 1/16 turn in the clockwise

direction.

4. Install the air cap and retaining ring onto the

applicator.

Figure 21: Reinstalling Fluid Nozzle

†

DO NOT under-tighten the fluid nozzle

as fluid can leak into the air passages.

†

DO NOT over-tighten the fluid nozzle

into the barrel. Doing so could damage

or break the fluid nozzle or damage the

thread of the barrel.

NEEDLE / ELECTRODE

Removal

1. Remove the air cap and fluid nozzle from the

applicator assembly.

2. Secure the needle shaft at the rear of the barrel

with the Special Wrench 79854-00 and unscrew

the needle/electrode from the needle shaft.

Cleaning and Inspection

1. Use a suitable solvent to clean the needle/

electrode.

2. Examine the needle/electrode for damage or

wear. Pay special attention to the area where

the wire electrode extends from the main body.

This is a sealing surface that seats inside the fluid

nozzle. If there are signs of wear in this area,

both the needle/electrode and fluid nozzle must

be replaced.

3. An electrical check of the needle/electrode must

be done prior to reinstalling it into the applicator

assembly (refer to "Needle/Electrode Resistance

Testing" in the "Maintenance" section).

Reinstall

1. Secure the needle shaft at the rear of the barrel

and screw the needle/electrode into place by hand.

2. Reinstall the fluid nozzle and air cap onto the

barrel.

Figure 22: Electrode Removal

C W
3 5 -4 0

L B S -I N

3 . 9 -4 . 5 N M

NOTE

Ransburg

Advertising