Vector Solo 65kV Applicator - Maintenance

28

AH-08-02.6

Figure 30: Cascade/One Way Valve Removal

Remove Cascade

1. Pull the cascade out of the barrel.

2. Wipe off excess dielectric lubricant.

3. Remove excess lubricant from inside barrel

with a clean cloth or rag.

4. Remove one-way valves.

Replace Cascade

1. Dispense about 1/4 tube of LSCH0009-00 Di-

electric Grease inside the barrel and on the sides

of the cascade.

Figure 31: Cascade/One Way Valve Installation

Reinstalling Barrel

1. Replace the hook. Install the barrel against

the handle and hand tighten two (2) long 5mm

screws, in an alternating sequence with the 4mm

Allen wrench. Tighten the hook screw with the

same 4mm wrench.

2. Install the first jam nut. Tighten to stop by hand

while holding the needle shaft.

Figure 33: First Jam Nut Replacement

Figure 32: Installing Barrel to Handle

2. Slide the cascade back into the barrel.

3. Install one-way valves into air passages as

shown.

†

Failure to use the LSCH0009-00 may

shorten product life.

C A U T I O N

!

1 - 79793 Removal Tool

2 - 1st Jam Nut

3 - 79854 Special Wrench

4 - 2nd Jam Nut (Raised Center)

Ransburg