Vector Solo 65kV Applicator - Maintenance

40

AH-08-02.6

TROUBLESHOOTING GUIDE

General Problem

Possible Cause

Solution

INADEQUATE DELIVERY

ELECTRICAL

Ensure the On/Off lever is in the On

position.

Ensure 40 psig (2.75 bar) at the applicator

handle with applicator triggered.

Ensure the air hose is properly grounded to

the earth ground.

Ensure cascade is functioning properly.

Tighten screws to ensure proper assembly.

Ensure module is properly functioning.

a. Clean air passages with non-polar

solvent.

b. Ensure fluid nozzle is properly tightened.

Use non-polar solvent for the final

cleaning process.

Ensure 2.8 bar (40 psig) at the handle

with applicator triggered.

Ensure pressure at the fluid line at the

applicator.

Replace or clean.

Replace or clean.

Reassemble tightened to stop.

Thin the material to a viscosity that is

sprayable.

a. Restrictor left out of barrel.

b. The three (3) 5mm barrel to handle

screws are not properly tightened.

Ensure atomization air passages are

clear of all foreign particles.

Ensure fluid nozzle is properly tightened.

On-Off lever in wrong position

Low pressure

No ground connection

Cascade not functioning

Three (3) screws at base of handle

are loose

Failed power module

Fluid remnants in the air passage

Wrong solvent used for final cleaning

process

Add sufficient air pressure at handle

No pressure

Fluid tube may be plugged

Fluid nozzle may be plugged

Electrode not properly assembled

Material too viscous

No adjustment of fan pattern

Poor atomization

Fluid in air passages

Spray

Performance

No Fluid Flow

Low kV

No kV