Handle disassembly, Ransburg, Vector solo 65kv applicator - maintenance – Ransburg Vector Solo 65KV 79965 Solventborne RS70-AS User Manual

Page 36

Advertising
background image

Vector Solo 65kV Applicator - Maintenance

32

AH-08-02.6

4. Remove the rear seal.

Figure 48: Rear Seal Removal

5. Using a dowel rod, push out the air valve

cartridge.

Figure 49: Air Valve Cartridge Removal

Figure 47: Air Valve Removal

Handle Disassembly

1. Remove barrel.

2. Remove power module.

3. Push air valve out.

Figure 46: Power Module Removal

†

The power modules are not serviceable.

NOTE

1 - Push Out From Here

1 - 6mm (1/4") Dowel

3. Pull the module straight off the handle.

Ransburg