Vector Solo 65kV Applicator - Maintenance

21

AH-08-02.6

ROUTINE SCHEDULE

Follow these maintenance steps to extend the

life of the applicator and ensure efficient operation:

Several Times Daily

• Inspect the air cap for paint accumulation.

Clean as frequently as necessary with a soft

bristled brush and a suitable solvent.

• Clean all insulating surfaces in the system.

Remove paint accumulation from the exterior

of the applicator with a solvent dampened

cloth.

Daily (or at start of each shift)

• Verify that ALL solvent safety containers

are grounded!

• Check within 6m (20-ft.) of the point of opera-

tion (of the applicator) and remove or ground

ALL loose or ungrounded objects.

• Inspect work holders for accumulated coat-

ing materials (and remove such accumula-

tions).

• Check that atomizer assembly is clean and

undamaged.

†

NEVER soak or submerge the electrical

components of the applicator, i.e., barrel,

power module, or handle. Damage and

failure may occur.

C A U T I O N

!

†

NEVER remove the fluid nozzle assem-

bly while paint is in the applicator or paint

may enter into the air passages. Clogged

or restricted air passages will cause poor

atomization and/or electrical shorting. Air

passages that are clogged with conductive

material can lead to excessive current out-

put levels and consequent low operating

voltage or long-term electrical damage.

The applicator barrel

MUST be tilted front

down to remove the fluid nozzle. Failure to do

so may allow paint to enter the air passages,

thereby reducing airflow and damaging the

applicator barrel/cascade. Applicators may

be flushed in lieu of tilting. However, they

must be either flushed or tilted down during

nozzle removal!

C A U T I O N

!

• Straighten the applicator electrode if neces-

sary.

• Clean the fluid filter, if used.

Electrical Output Test

1. Turn the paint and/or solvent supply OFF.

†

Standard electrode is "snap back"

spray wire electrode.

NOTE

†

Paint and/or solvent supply must be

turned off during this test - risk of fire or

explosion.

W A R N I N G

!

2. Flush the applicator (see "Flushing Proce-

dure" in the "Operation" section).

3. Follow instructions for use of the 76634-00

Meter.

Ransburg