Power module - fluid fitting removal, Ransburg, Vector solo 65kv applicator - maintenance – Ransburg Vector Solo 65KV 79965 Solventborne RS70-AS User Manual

Page 38

Advertising
background image

Vector Solo 65kV Applicator - Maintenance

34

AH-08-02.6

Figure 57: Fluid Fitting Removal

Power Module - Fluid Fitting Removal

1. Remove power module from handle.

2. Remove two (2) screws using a 2.5mm Allen wrench.

4. Install the rear seal.

5. Install air valve.

Figure 54: Rear Cartridge Seal Replacement

Figure 55: Air Valve Replacement

Figure 56: Power Module Removal

Figure 53: Air Valve Cartridge Alignment

3. Install the air valve cartridge. Align the cartridge

with tab at 12 o'clock posiition.

6. Reinstall barrel.

7. Install power module.