Power module - fluid fitting removal, Ransburg, Vector solo 65kv applicator - maintenance – Ransburg Vector Solo 65KV 79965 Solventborne RS70-AS User Manual
Page 38
Advertising
![background image](/manuals/348078/38/background.png)
Vector Solo 65kV Applicator - Maintenance
34
AH-08-02.6
Figure 57: Fluid Fitting Removal
Power Module - Fluid Fitting Removal
1. Remove power module from handle.
2. Remove two (2) screws using a 2.5mm Allen wrench.
4. Install the rear seal.
5. Install air valve.
Figure 54: Rear Cartridge Seal Replacement
Figure 55: Air Valve Replacement
Figure 56: Power Module Removal
Figure 53: Air Valve Cartridge Alignment
3. Install the air valve cartridge. Align the cartridge
with tab at 12 o'clock posiition.
6. Reinstall barrel.
7. Install power module.
Ransburg
Advertising