Ransburg, Vector solo 65kv applicator - maintenance – Ransburg Vector Solo 65KV 79965 Solventborne RS70-AS User Manual

Page 31

Advertising
background image

Vector Solo 65kV Applicator - Maintenance

27

AH-08-02.6

4. Remove the trigger and fluid line.

Figure 26: Fluid Line/Trigger Removal

5. Remove the two (2) jam nuts using the 79793-

00 Removal Tool while holding the needle shaft

with the 79854-00 Special Wrench.

Figure 27: Jam Nut Removal

6. Remove three (3) 5mm screws using a 4mm

Allen wrench. Remove the hook.

Figure 28: Barrel Screw Removal

7. Pull the barrel straight away from the handle.

Figure 29: Barrel Removal

Ransburg

Advertising