Vector Solo 65kV Applicator - Installation

14

1. Ensure there is a true earth ground connection

available.

†

Both the fluid source and the air hose

ground must be connected to true earth

ground.

W A R N I N G

!

Figure 3: Voltage Off Lever Position

(Bottom View)

Figure 4: Air Hose Connections

Figure 5: Fluid Hose Connection

Interlocks Required

Interlock the solvent supply with the main supply

air to the applicator. When solvent is On, main

supply air to the applicator is Off. Interlocks are

user supplied.

†

The solvent supply must be interlocked

with applicator supply air.

W A R N I N G

!

INSTALLATION

2. Connect the fluid source to true earth ground.

3. Ensure electrostatic On/Off lever is in the Off

position.

4. Connect the air hose ground wire to true earth

ground.

7. Trigger the applicator with fluid off. Look for air

leaks in any connections.

8. Activate fluid, check for leaks with solvent.

Flush if required. (See "Operation" section for

sequence.)

C W

C C W

C C W

5. Connect the air hose to the applicator,

thread

is left hand pitch, counter-clockwise to tighten.

6. Connect fluid hose from grounded fluid source.

AH-08-02.6

Ransburg

†

It is the end users responsibility to insure

the ground end of the 79727-XX air hose is

connected to true earth ground.

W A R N I N G

!