Vector Solo 65kV Applicator - Operation

17

AH-08-02.6

Figure 12: Electrostatics Lever Off Position

FLUSHING / COLOR

CHANGE PROCEDURE

1. Turn electrostatic lever to Off position.

Figure 10: Fan Pattern Size Adjustment

5. Adjust fan pattern size. Counter-clockwise

makes the pattern longer; clockwise makes the

pattern shorter. Full clockwise creates a small

circular pattern.

6. To change the spray pattern axis of fan atomizers

from horizontal to vertical, loosen the air nozzle

retaining ring, rotate the air cap clockwise to the

desired position, and tighten the ring.

7. Use the "Fluid Nozzle Selection Chart and

Air Cap/Fluid Nozzle Performance Chart" in the

"Installation" section to select the proper air cap

and fluid nozzle for the applications.

8. The applicator is shipped standard with a plug

in the atomization air port. If lower atomization

air pressures are desired, a compensation valve

is included with each applicator and can be used

instead of the plug. The compensation valve

(included separate with applicator) reduces the

atomization air pressure approximately 0.2 bar

(3 psig) per clockwise turn from the wide open

position. To determine what pressure the applicator

is set at, use the Air Cap Test Kit in "Accessories"

in the "Parts Identification" section.

Figure 11: Compensation Valve -

Full Open Position

79727

Hose Length

30m
20m
15m
10m

Table I - Pressure at Regulator

Pressure At

Wall Regulator Gauge

5.9 bar (85 psig)
4.8 bar (70 psig)
4.5 bar (65 psig)
4.1 bar (60 psig)