Vector Solo 65kV Applicator - Maintenance

39

AH-08-02.6

3. With the 79330 fitting, hold the hose in one hand

and press a 6mm or 1/4" t-handle allen wrench

into the hex in the part while turning clockwise.

Tighten till cap is approximately .8 mm (1/32")

from the swivel nut.

Resistance Test

1. If the hose is changed, the resistance must

be checked. Using a Meg Ohm meter at 1000V

measure the resistance from the lug of the ground

wire to the body of the QD (79868) or the swivel

nut (79930). The reading must be less than .5

Mega Ohms resistance end to end.

Figure 74: Tightening 79930 Fitting

4. With the 79868 DQ fitting, hold the hose in one

hand and press against a firm surface while turning

the body wrench flat clockwise. Tighten till cap is

approximately .8 mm (1/32") from the QD base.

Figure 75: Tightening 79868 QD Fitting

Figure 76: Air Hose Resistance Test