Vector Solo 65kV Applicator - Maintenance

33

AH-08-02.6

6. Remove air valve cartridge seal (black) (see

Figure 48).

7. Remove front air valve seal (white).

Figure 50: Air Valve Cartridge Seal and Front

Seal Removal

Figure 52: Cartridge Seal Replacement

2. Install the air valve cartridge seal.

Figure 51: Air Valve Seal Replacement

†

If you remove the air valve seal, it is

highly recommended that it is replaced.

NOTE

Handle Rebuild

1. Install the front air valve seal using the Special

Tool.

1 - Rear Seal

2 - Air Valve Cartridge Seal

3 - Front Air Valve Seal

1 - 79793-00 Jam Nut Tool

2 - Front Air Valve Seal - Concave Side to Tool

†

Only remove the front air valve seal

(item 3) if there is damage or wear to the

seal causing leakage.

NOTE

Ransburg