• If ignitable fluids are used for cleaning purposes,

all parts must be completely discharged of high

voltage.

• The fluid supply system must be properly

grounded.

• If an object is within the 204mm safe distance,

it must be cleared prior to restarting and/or re-en-

ergizing the system.

• The type AB168 Electrostatic Bell and type

9060 (80120-51X or 80100-51X) power supply

complies with EN 50 176: 2009. Clauses 4,

5.1, 5.2.1, 5.2.2, 5.2.3, 5.2.4, 5.3, 5.5.1, 5.5.3,

5.5.5, 5.6, 6.1, 6.4, 7.2, 7.3 and 7.4. All remain-

ing clauses of EN 50 176: 2009 are to be ad-

dressed during installation.

AB168 A13350 ATEX PRODUCT

MARKING DEFINITIONS

Ex Certificate Number: Sira 13ATEX5176X

Sira = Notified Body performing EC-type

examination

13 = Year of certification

ATEX = Reference to ATEX Directive

5 = Protection Concept Code (code 5 is titled

Encapsulation)

176 = Document serial number

X = Special conditions for safe use apply

Product Marking

Ex = Specific marking of explosive protection

II = Equipment Group hazardous area

characteristics

2 = Equipment Category

G = Type of explosive atmosphere (gases,

vapors, or mists)

T6 = Temperature classification.

Special conditions for safe use:
• The AB168, Applicator shall only be used with

associated 80120-51X or 80100-51X 9060 Power

Supply according to configuration drawing A13351.

• The safe Distance of use for the Type AB168

Electrostatic Bell is 204mm minimum; from the

electrode to earthed parts. The end user must

ensure this distance, as a minimum is maintained

and that grounded objects are prevented from

contacting the applicator bell cup when the ap-

plicator is energized or operating.

• The 9060 and external cascade is intended for

“Safe Area Use” only.

• The AB168 Electrostatic Bell is a potential hazard

- refer to the manufacturers instructions.

• The end user must insure that installation is in

accordance with all applicable requirements of EN

50 176. This includes the means of fire protection

and fire detection being installed with this system.

• Before servicing bell insure that all voltage is

completely de-energized and the bell cup is not

rotating. Minimum 1 minute wait after turbine air

has been shut off.

Configurations

These applicators are approved when configured

to drawings shown on pages 8 thru 13.

II 2 G T6

0518

II (2) G

0518

Power Supply Marking

E N 5 0 1 7 6 COM P L I A N T

80108

A13383

A13384

A13349

Aerobell 168 - Atex

Ransburg

LN-9247-13

7