Atex labels, Ransburg, Configurations – Ransburg Aerobell 168 Atex Approved 13350 User Manual
Page 10: Aerobell 168 - atex
![background image](/manuals/348100/10/background.png)
• If ignitable fluids are used for cleaning purposes,
all parts must be completely discharged of high
voltage.
• The fluid supply system must be properly
grounded.
• If an object is within the 204mm safe distance,
it must be cleared prior to restarting and/or re-en-
ergizing the system.
• The type AB168 Electrostatic Bell and type
9060 (80120-51X or 80100-51X) power supply
complies with EN 50 176: 2009. Clauses 4,
5.1, 5.2.1, 5.2.2, 5.2.3, 5.2.4, 5.3, 5.5.1, 5.5.3,
5.5.5, 5.6, 6.1, 6.4, 7.2, 7.3 and 7.4. All remain-
ing clauses of EN 50 176: 2009 are to be ad-
dressed during installation.
AB168 A13350 ATEX PRODUCT
MARKING DEFINITIONS
Ex Certificate Number: Sira 13ATEX5176X
Sira = Notified Body performing EC-type
examination
13 = Year of certification
ATEX = Reference to ATEX Directive
5 = Protection Concept Code (code 5 is titled
Encapsulation)
176 = Document serial number
X = Special conditions for safe use apply
Product Marking
Ex = Specific marking of explosive protection
II = Equipment Group hazardous area
characteristics
2 = Equipment Category
G = Type of explosive atmosphere (gases,
vapors, or mists)
T6 = Temperature classification.
Special conditions for safe use:
• The AB168, Applicator shall only be used with
associated 80120-51X or 80100-51X 9060 Power
Supply according to configuration drawing A13351.
• The safe Distance of use for the Type AB168
Electrostatic Bell is 204mm minimum; from the
electrode to earthed parts. The end user must
ensure this distance, as a minimum is maintained
and that grounded objects are prevented from
contacting the applicator bell cup when the ap-
plicator is energized or operating.
• The 9060 and external cascade is intended for
“Safe Area Use” only.
• The AB168 Electrostatic Bell is a potential hazard
- refer to the manufacturers instructions.
• The end user must insure that installation is in
accordance with all applicable requirements of EN
50 176. This includes the means of fire protection
and fire detection being installed with this system.
• Before servicing bell insure that all voltage is
completely de-energized and the bell cup is not
rotating. Minimum 1 minute wait after turbine air
has been shut off.
Configurations
These applicators are approved when configured
to drawings shown on pages 8 thru 13.
II 2 G T6
0518
II (2) G
0518
Power Supply Marking
E N 5 0 1 7 6 COM P L I A N T
80108
A13383
A13384
A13349
Aerobell 168 - Atex
Ransburg
LN-9247-13
7