GENERAL INFORMATION

This information is intended ONLY to indicate the

general installation parameters of this product

and, where applicable, its working relationship to

other Ransburg system components in typical use.

Each installation is unique and should be direct-

ed by an authorized Ransburg representative

or conducted using the Ransburg installation

drawings provided for your particular installation.

AIR FILTER INSTALLATION

The following guidelines must be observed when

installing air filters for the Aerobell 168 system (see

“Air Filtration Requirements Chart” for additional

information).

1. Use only recommended pre-filters and bearing

air filters as shown in “Recommended Air Filtration

Requirements” in this section. Additional system

air filtration (i.e., refrigerated air dryer) may also

be used if desired.

2. Use one bearing air filter per Aerobell.

3. Mount the bearing air filter as close as possible

to the Aerobell 168 (do not mount further than 30

feet (9M) away).

4. Where possible, the pre-filter(s) and bearing

air filter(s) should be mounted where they can be

easily seen, so the user will see when maintenance

is required.

5. Standard black iron or galvanized piping may

be used prior to the HAF-503 or HAF-508 pre-fil-

ters only. All piping after the pre-filter should be

brass, stainless steel, aluminum, or hose (poly,

nylon, nyliner, etc.).

6.

Do not use PTFE tape, pipe dope, or other

thread sealant downstream of the bearing air filter.

Loose flakes of PTFE tape or other sealant can

break loose and plug the very fine air holes in the

turbine bearings.

7. Use clear see-through air tubing between the

bearing air filter and bearing air fitting to clearly

indicate to the user if oil or moisture contamination

is getting past the filter.

8. If air heaters are used in the system (to mini-

mize the effect of excessively humid conditions),

and the heated air will exceed 120°F, the heaters

must be located after all filters to prevent damage

to the filter media.

†

Risk of arcing/fire hazard. The Aerobell

168 must be located a safe distance from

the object to be sprayed, as well as all oth-

er grounded objects. The safe distance is

204mm (8”).

†

This must be installed with fire protection

and fire detection per EN 50 176.

†

Power Unit must be interlocked with con-

veyor and booth fan.

INSTALLATION

†

The Aerobell 168 shipping container in-

cludes the basic atomizer assembly with

bell and manifold. Tool options for bell cup

removal and dis-assembly of other compo-

nents can be purchased with the atomizers

or ordered separately.

†

Mount the Aerobell 168 securely to a sta-

tionary or reciprocating fixture with the 3/4-

inch (19MM) diameter stud provided.